Sewerin acoustic leak detection equipment
Ground microphones and listening sticks that pick up the high-frequency sound of pressurized water escaping a pipe through concrete and soil.
RIDGID acoustic listening system
Used for grid sweeps across slabs and walls. The RIDGID platform gives us frequency filtering to isolate leak sounds from ambient noise like HVAC or traffic.
FLIR thermal imaging camera
Detects temperature differences on the slab surface. Hot water line leaks show as warm spots, and cold line leaks show as cool spots, confirming acoustic hits.
Pipe locator
Traces the underground route of supply lines so we know exactly which pipe we're listening over. Prevents false positives from gas, drain, or irrigation lines.
Pressure testing gauge
Isolates the supply system and confirms whether the leak is on the pressurized side. A system that won't hold pressure tells us the leak is on a supply line.
Video pipe inspection camera
Used on drain and sewer lines when acoustic testing suggests a non-pressurized leak. The camera shows cracks, root intrusion, and cast iron pipe failure directly.
Moisture meter
Confirms elevated moisture readings at the acoustic hit location. We use it as a third confirmation signal before marking the floor for repair access.